No Cover Image

Journal article 788 views 164 downloads

Identification of modal parameters from noisy transient response signals

Dan He, Xiufeng Wang, Michael Friswell, Jing Lin

Structural Control and Health Monitoring, Start page: e2019

Swansea University Author: Michael Friswell

Check full text

DOI (Published version): 10.1002/stc.2019

Abstract

In the process of impact testing of large-scale mechanical equipment, the measured forced response signals are often polluted by strong background noise. The forced response signal has a low signal-to-noise ratio, and this makes it difficult to accurately estimate the modal parameters. To solve this...

Full description

Published in: Structural Control and Health Monitoring
ISSN: 15452255
Published: 2017
Online Access: Check full text

URI: https://cronfa.swan.ac.uk/Record/cronfa33695
Tags: Add Tag
No Tags, Be the first to tag this record!
Abstract: In the process of impact testing of large-scale mechanical equipment, the measured forced response signals are often polluted by strong background noise. The forced response signal has a low signal-to-noise ratio, and this makes it difficult to accurately estimate the modal parameters. To solve this problem, the mean averaging of repeatedly measured frequency response function estimates is often employed in practical applications. However, a large number of impact tests are not practical for the modal testing of large-scale mechanical equipment. The primary objective of this paper is to reduce the averaging operation and improve the accuracy of the modal identification by using a noise removal technique. A hybrid denoising method is proposed by combining the Wiener and improved minimum mean-square-error short-time spectral amplitude estimators. The proposed method can effectively remove both stationary and highly nonstationary noise while preserving the important features of the true forced response signals. The simulation results show that the proposed noise removal technique improves the accuracy of the estimated modal parameters using only one impulse response signal. The experimental results show that the proposed method can accurately identify a natural frequency that is very close to a strong interference frequency in the modal test of a 600-MW generator casing.
Keywords: hybrid method; low SNR; MMSE-STSA estimator; modal identification; WIENER-STSA estimator
College: Faculty of Science and Engineering
Start Page: e2019