Toward Pulse by Pulse Dosimetry Using an SC CVD Diamond Detector

J. J. Velthuis, R. F. Page, T. M. Purves, L. Beck, M. A. M. Hanifa, R. P. Hugtenburg, Richard Hugtenburg Orcid Logo

IEEE Transactions on Radiation and Plasma Medical Sciences, Volume: 1, Issue: 6, Pages: 527 - 533

Swansea University Author: Richard Hugtenburg Orcid Logo

Abstract

Solid state detectors with nanosecond response timesto incoming radiation are increasingly present at the forefrontof radiotherapy dosimetry research. The fast response time ofmaterials, such as diamond, allow pulse by pulse dosimetry. Thereis a trend in radiotherapy to move towards shorter treatmen...

Full description

Published in: IEEE Transactions on Radiation and Plasma Medical Sciences
ISSN: 2469-7311 2469-7303
Published: 2017
Online Access: Check full text

URI: https://cronfa.swan.ac.uk/Record/cronfa36274
Tags: Add Tag
No Tags, Be the first to tag this record!
first_indexed 2017-10-26T13:34:22Z
last_indexed 2018-02-09T05:28:21Z
id cronfa36274
recordtype SURis
fullrecord <?xml version="1.0"?><rfc1807><datestamp>2017-11-29T13:14:44.8166174</datestamp><bib-version>v2</bib-version><id>36274</id><entry>2017-10-26</entry><title>Toward Pulse by Pulse Dosimetry Using an SC CVD Diamond Detector</title><swanseaauthors><author><sid>efd2f52ea19cb047e01a01e6fa6fa54c</sid><ORCID>0000-0003-0352-9607</ORCID><firstname>Richard</firstname><surname>Hugtenburg</surname><name>Richard Hugtenburg</name><active>true</active><ethesisStudent>false</ethesisStudent></author></swanseaauthors><date>2017-10-26</date><deptcode>MEDP</deptcode><abstract>Solid state detectors with nanosecond response timesto incoming radiation are increasingly present at the forefrontof radiotherapy dosimetry research. The fast response time ofmaterials, such as diamond, allow pulse by pulse dosimetry. Thereis a trend in radiotherapy to move towards shorter treatments,using fewer but more intense pulses with varying pulse rates andintensities. This makes the possibility of measuring individualpulses very attractive and would allow intervention during thetreatment and not just afterwards. Here an analogue front endhas been developed and combined with a CVD diamond detectorto provide real time, pulse by pulse beam intensity measure-ments.The front end design is discussed and the experimentalresults obtained using a medical LINAC are presented. Theresults show that pulse by pulse The device is capable of pulseby pulse beam intensity measurements up to pulse rates wellabove 1 kHz. The system performs so well that its variations arenegligible compared to the pulse to pulse intensity variations.The dosimetric performance of our system was compared toa commercially available, integrating diamond detector, themicroDiamond by PTW. The dose and dose-rate linearity of oursystem is comparable with the one of the microDiamond and hasthe additional advantage of being able to measure the depositeddose per pulse.</abstract><type>Journal Article</type><journal>IEEE Transactions on Radiation and Plasma Medical Sciences</journal><volume>1</volume><journalNumber>6</journalNumber><paginationStart>527</paginationStart><paginationEnd>533</paginationEnd><publisher/><issnPrint>2469-7311</issnPrint><issnElectronic>2469-7303</issnElectronic><keywords/><publishedDay>14</publishedDay><publishedMonth>9</publishedMonth><publishedYear>2017</publishedYear><publishedDate>2017-09-14</publishedDate><doi>10.1109/TRPMS.2017.2750799</doi><url/><notes/><college>COLLEGE NANME</college><department>Medical Physics</department><CollegeCode>COLLEGE CODE</CollegeCode><DepartmentCode>MEDP</DepartmentCode><institution>Swansea University</institution><apcterm/><lastEdited>2017-11-29T13:14:44.8166174</lastEdited><Created>2017-10-26T10:48:28.7126458</Created><path><level id="1">Faculty of Medicine, Health and Life Sciences</level><level id="2">Swansea University Medical School - Medicine</level></path><authors><author><firstname>J. J.</firstname><surname>Velthuis</surname><order>1</order></author><author><firstname>R. F.</firstname><surname>Page</surname><order>2</order></author><author><firstname>T. M.</firstname><surname>Purves</surname><order>3</order></author><author><firstname>L.</firstname><surname>Beck</surname><order>4</order></author><author><firstname>M. A. M.</firstname><surname>Hanifa</surname><order>5</order></author><author><firstname>R. P.</firstname><surname>Hugtenburg</surname><order>6</order></author><author><firstname>Richard</firstname><surname>Hugtenburg</surname><orcid>0000-0003-0352-9607</orcid><order>7</order></author></authors><documents><document><filename>0036274-14112017105232.pdf</filename><originalFilename>VelthuisET_diamondv2.pdf</originalFilename><uploaded>2017-11-14T10:52:32.1000000</uploaded><type>Output</type><contentLength>1029683</contentLength><contentType>application/pdf</contentType><version>Accepted Manuscript</version><cronfaStatus>true</cronfaStatus><embargoDate>2017-11-14T00:00:00.0000000</embargoDate><copyrightCorrect>true</copyrightCorrect><language>eng</language></document></documents><OutputDurs/></rfc1807>
spelling 2017-11-29T13:14:44.8166174 v2 36274 2017-10-26 Toward Pulse by Pulse Dosimetry Using an SC CVD Diamond Detector efd2f52ea19cb047e01a01e6fa6fa54c 0000-0003-0352-9607 Richard Hugtenburg Richard Hugtenburg true false 2017-10-26 MEDP Solid state detectors with nanosecond response timesto incoming radiation are increasingly present at the forefrontof radiotherapy dosimetry research. The fast response time ofmaterials, such as diamond, allow pulse by pulse dosimetry. Thereis a trend in radiotherapy to move towards shorter treatments,using fewer but more intense pulses with varying pulse rates andintensities. This makes the possibility of measuring individualpulses very attractive and would allow intervention during thetreatment and not just afterwards. Here an analogue front endhas been developed and combined with a CVD diamond detectorto provide real time, pulse by pulse beam intensity measure-ments.The front end design is discussed and the experimentalresults obtained using a medical LINAC are presented. Theresults show that pulse by pulse The device is capable of pulseby pulse beam intensity measurements up to pulse rates wellabove 1 kHz. The system performs so well that its variations arenegligible compared to the pulse to pulse intensity variations.The dosimetric performance of our system was compared toa commercially available, integrating diamond detector, themicroDiamond by PTW. The dose and dose-rate linearity of oursystem is comparable with the one of the microDiamond and hasthe additional advantage of being able to measure the depositeddose per pulse. Journal Article IEEE Transactions on Radiation and Plasma Medical Sciences 1 6 527 533 2469-7311 2469-7303 14 9 2017 2017-09-14 10.1109/TRPMS.2017.2750799 COLLEGE NANME Medical Physics COLLEGE CODE MEDP Swansea University 2017-11-29T13:14:44.8166174 2017-10-26T10:48:28.7126458 Faculty of Medicine, Health and Life Sciences Swansea University Medical School - Medicine J. J. Velthuis 1 R. F. Page 2 T. M. Purves 3 L. Beck 4 M. A. M. Hanifa 5 R. P. Hugtenburg 6 Richard Hugtenburg 0000-0003-0352-9607 7 0036274-14112017105232.pdf VelthuisET_diamondv2.pdf 2017-11-14T10:52:32.1000000 Output 1029683 application/pdf Accepted Manuscript true 2017-11-14T00:00:00.0000000 true eng
title Toward Pulse by Pulse Dosimetry Using an SC CVD Diamond Detector
spellingShingle Toward Pulse by Pulse Dosimetry Using an SC CVD Diamond Detector
Richard Hugtenburg
title_short Toward Pulse by Pulse Dosimetry Using an SC CVD Diamond Detector
title_full Toward Pulse by Pulse Dosimetry Using an SC CVD Diamond Detector
title_fullStr Toward Pulse by Pulse Dosimetry Using an SC CVD Diamond Detector
title_full_unstemmed Toward Pulse by Pulse Dosimetry Using an SC CVD Diamond Detector
title_sort Toward Pulse by Pulse Dosimetry Using an SC CVD Diamond Detector
author_id_str_mv efd2f52ea19cb047e01a01e6fa6fa54c
author_id_fullname_str_mv efd2f52ea19cb047e01a01e6fa6fa54c_***_Richard Hugtenburg
author Richard Hugtenburg
author2 J. J. Velthuis
R. F. Page
T. M. Purves
L. Beck
M. A. M. Hanifa
R. P. Hugtenburg
Richard Hugtenburg
format Journal article
container_title IEEE Transactions on Radiation and Plasma Medical Sciences
container_volume 1
container_issue 6
container_start_page 527
publishDate 2017
institution Swansea University
issn 2469-7311
2469-7303
doi_str_mv 10.1109/TRPMS.2017.2750799
college_str Faculty of Medicine, Health and Life Sciences
hierarchytype
hierarchy_top_id facultyofmedicinehealthandlifesciences
hierarchy_top_title Faculty of Medicine, Health and Life Sciences
hierarchy_parent_id facultyofmedicinehealthandlifesciences
hierarchy_parent_title Faculty of Medicine, Health and Life Sciences
department_str Swansea University Medical School - Medicine{{{_:::_}}}Faculty of Medicine, Health and Life Sciences{{{_:::_}}}Swansea University Medical School - Medicine
document_store_str 1
active_str 0
description Solid state detectors with nanosecond response timesto incoming radiation are increasingly present at the forefrontof radiotherapy dosimetry research. The fast response time ofmaterials, such as diamond, allow pulse by pulse dosimetry. Thereis a trend in radiotherapy to move towards shorter treatments,using fewer but more intense pulses with varying pulse rates andintensities. This makes the possibility of measuring individualpulses very attractive and would allow intervention during thetreatment and not just afterwards. Here an analogue front endhas been developed and combined with a CVD diamond detectorto provide real time, pulse by pulse beam intensity measure-ments.The front end design is discussed and the experimentalresults obtained using a medical LINAC are presented. Theresults show that pulse by pulse The device is capable of pulseby pulse beam intensity measurements up to pulse rates wellabove 1 kHz. The system performs so well that its variations arenegligible compared to the pulse to pulse intensity variations.The dosimetric performance of our system was compared toa commercially available, integrating diamond detector, themicroDiamond by PTW. The dose and dose-rate linearity of oursystem is comparable with the one of the microDiamond and hasthe additional advantage of being able to measure the depositeddose per pulse.
published_date 2017-09-14T03:45:18Z
_version_ 1763752142316765184
score 11.012678