Journal article 1058 views 154 downloads
Personalising cardiovascular network models in pregnancy: A two‐tiered parameter estimation approach
International Journal for Numerical Methods in Biomedical Engineering
Swansea University Authors: Jason Carson , Raoul van Loon
-
PDF | Version of Record
Released under the terms of a Creative Commons Attribution License (CC-BY).
Download (3.23MB)
DOI (Published version): 10.1002/cnm.3267
Abstract
Uterine artery Doppler waveforms are often studied to determine whether a patient is at risk of developing pathologies such as pre-eclampsia. Many uterine waveform indices have been developed, which attempt to relate characteristics of the waveform with the physiological adaptation of the maternal c...
Published in: | International Journal for Numerical Methods in Biomedical Engineering |
---|---|
ISSN: | 2040-7939 2040-7947 |
Published: |
Wiley
2020
|
Online Access: |
Check full text
|
URI: | https://cronfa.swan.ac.uk/Record/cronfa52055 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Abstract: |
Uterine artery Doppler waveforms are often studied to determine whether a patient is at risk of developing pathologies such as pre-eclampsia. Many uterine waveform indices have been developed, which attempt to relate characteristics of the waveform with the physiological adaptation of the maternal cardiovascular system, and are often suggested to be an indicator of increased placenta resistance and arterial stiffness.Dopplerwaveforms of four patients, two of whom developed pre-eclampsia, are compared with a comprehensive closed-loop model of pregnancy. The closed-loop model has been previously validated, but has been extended to include an improved parameter estimation technique that utilises systolic and diastolic blood pressure, cardiac output, heart rate, and pulse wave velocity measurements to adapt model resistances, compliances, blood volume, and the mean vessel areas in the main systemic arteries. The shape of the model-predicted uterine artery velocity waveforms showed good agreement with the characteristics observed in the patient Doppler waveforms. The personalised models obtained now allow a prediction of the uterine pressure waveforms in addition to the uterine velocity. This allows for a more detailed mechanistic analysis of the waveforms, e.g. wave intensity analysis, to study existing clinical indices. The findings indicate that to accurately estimate arterial stiffness, both pulse pressure and pulse wave velocities are required. In addition the results predict that patients who developed pre-eclampsia later in pregnancy have larger vessel areas in the main systemic arteries compared to the two patients who had normal pregnancy outcomes. |
---|---|
Keywords: |
parameter estimation, personalised haemodynamic model, pre-eclampsia, pregnancy, uterine artery waveform |
College: |
Faculty of Science and Engineering |
Funders: |
UKRI, MRC |