Abstract

Mass spectrometry is a gold-standard analytical technique and is widely employed over a range of fields, from petrochemical, fine chemical through to medical applications. The types of instrumentation for sample separation, ionisation, mass analysis and detection that have evolved in analytical mass...

Full description

Published in: Spectroscopy Europe
ISSN: 2634-2561
Published: IM Publications Open LLP 2021
Online Access: Check full text

URI: https://cronfa.swan.ac.uk/Record/cronfa58901
Tags: Add Tag
No Tags, Be the first to tag this record!
first_indexed 2021-12-06T11:34:10Z
last_indexed 2022-01-01T04:25:19Z
id cronfa58901
recordtype SURis
fullrecord <?xml version="1.0"?><rfc1807><datestamp>2021-12-31T11:45:18.4237158</datestamp><bib-version>v2</bib-version><id>58901</id><entry>2021-12-06</entry><title>&#x201C;GlowFlow&#x201D;, a step towards a unified ionisation source for mass spectrometry?</title><swanseaauthors><author><sid>d58c5d38a44d72be924cdf2e1b62ad9f</sid><ORCID>0000-0002-3109-6653</ORCID><firstname>Rhodri</firstname><surname>Owen</surname><name>Rhodri Owen</name><active>true</active><ethesisStudent>false</ethesisStudent></author><author><sid>b17cebaf09b4d737b9378a3581e3de93</sid><ORCID>0000-0001-7991-5040</ORCID><firstname>Steven</firstname><surname>Kelly</surname><name>Steven Kelly</name><active>true</active><ethesisStudent>false</ethesisStudent></author><author><sid>6ec1cbca144a41ccf2ee5d89e5587468</sid><ORCID>0000-0003-2600-2082</ORCID><firstname>Anthony</firstname><surname>Brenton</surname><name>Anthony Brenton</name><active>true</active><ethesisStudent>false</ethesisStudent></author></swanseaauthors><date>2021-12-06</date><deptcode>BMS</deptcode><abstract>Mass spectrometry is a gold-standard analytical technique and is widely employed over a range of fields, from petrochemical, fine chemical through to medical applications. The types of instrumentation for sample separation, ionisation, mass analysis and detection that have evolved in analytical mass spectrometry are diverse; as the old colloquialism goes &#x201C;it is a matter of horses for courses&#x201D;. Our &#x201C;GlowFlow&#x201D; source design based on an Argon flowing glow-discharge may satisfy part of that landscape.</abstract><type>Journal Article</type><journal>Spectroscopy Europe</journal><volume>33</volume><journalNumber>8</journalNumber><paginationStart>19</paginationStart><paginationEnd>19</paginationEnd><publisher>IM Publications Open LLP</publisher><placeOfPublication/><isbnPrint/><isbnElectronic/><issnPrint/><issnElectronic>2634-2561</issnElectronic><keywords/><publishedDay>23</publishedDay><publishedMonth>11</publishedMonth><publishedYear>2021</publishedYear><publishedDate>2021-11-23</publishedDate><doi>10.1255/sew.2021.a53</doi><url/><notes/><college>COLLEGE NANME</college><department>Biomedical Sciences</department><CollegeCode>COLLEGE CODE</CollegeCode><DepartmentCode>BMS</DepartmentCode><institution>Swansea University</institution><apcterm/><funders>Engineering and Physical Sciences Research Council (EP/R51312X/1) and from the ERDF/ Welsh Government funded BEACON project</funders><lastEdited>2021-12-31T11:45:18.4237158</lastEdited><Created>2021-12-06T11:30:44.7977822</Created><path><level id="1">Faculty of Medicine, Health and Life Sciences</level><level id="2">Swansea University Medical School - Medicine</level></path><authors><author><firstname>Rhodri</firstname><surname>Owen</surname><orcid>0000-0002-3109-6653</orcid><order>1</order></author><author><firstname>Steven</firstname><surname>Kelly</surname><orcid>0000-0001-7991-5040</orcid><order>2</order></author><author><firstname>Anthony</firstname><surname>Brenton</surname><orcid>0000-0003-2600-2082</orcid><order>3</order></author></authors><documents><document><filename>58901__21801__76af3d5cba874931a4bb3ea5348ce542.pdf</filename><originalFilename>58901.pdf</originalFilename><uploaded>2021-12-06T11:33:24.2752332</uploaded><type>Output</type><contentLength>1504753</contentLength><contentType>application/pdf</contentType><version>Version of Record</version><cronfaStatus>true</cronfaStatus><documentNotes>&#xA9; 2021 The Authors Published under a Creative Commons BY-NC-ND licence</documentNotes><copyrightCorrect>true</copyrightCorrect><language>eng</language><licence>https://creativecommons.org/licenses/by-nc-nd/4.0/</licence></document></documents><OutputDurs/></rfc1807>
spelling 2021-12-31T11:45:18.4237158 v2 58901 2021-12-06 “GlowFlow”, a step towards a unified ionisation source for mass spectrometry? d58c5d38a44d72be924cdf2e1b62ad9f 0000-0002-3109-6653 Rhodri Owen Rhodri Owen true false b17cebaf09b4d737b9378a3581e3de93 0000-0001-7991-5040 Steven Kelly Steven Kelly true false 6ec1cbca144a41ccf2ee5d89e5587468 0000-0003-2600-2082 Anthony Brenton Anthony Brenton true false 2021-12-06 BMS Mass spectrometry is a gold-standard analytical technique and is widely employed over a range of fields, from petrochemical, fine chemical through to medical applications. The types of instrumentation for sample separation, ionisation, mass analysis and detection that have evolved in analytical mass spectrometry are diverse; as the old colloquialism goes “it is a matter of horses for courses”. Our “GlowFlow” source design based on an Argon flowing glow-discharge may satisfy part of that landscape. Journal Article Spectroscopy Europe 33 8 19 19 IM Publications Open LLP 2634-2561 23 11 2021 2021-11-23 10.1255/sew.2021.a53 COLLEGE NANME Biomedical Sciences COLLEGE CODE BMS Swansea University Engineering and Physical Sciences Research Council (EP/R51312X/1) and from the ERDF/ Welsh Government funded BEACON project 2021-12-31T11:45:18.4237158 2021-12-06T11:30:44.7977822 Faculty of Medicine, Health and Life Sciences Swansea University Medical School - Medicine Rhodri Owen 0000-0002-3109-6653 1 Steven Kelly 0000-0001-7991-5040 2 Anthony Brenton 0000-0003-2600-2082 3 58901__21801__76af3d5cba874931a4bb3ea5348ce542.pdf 58901.pdf 2021-12-06T11:33:24.2752332 Output 1504753 application/pdf Version of Record true © 2021 The Authors Published under a Creative Commons BY-NC-ND licence true eng https://creativecommons.org/licenses/by-nc-nd/4.0/
title “GlowFlow”, a step towards a unified ionisation source for mass spectrometry?
spellingShingle “GlowFlow”, a step towards a unified ionisation source for mass spectrometry?
Rhodri Owen
Steven Kelly
Anthony Brenton
title_short “GlowFlow”, a step towards a unified ionisation source for mass spectrometry?
title_full “GlowFlow”, a step towards a unified ionisation source for mass spectrometry?
title_fullStr “GlowFlow”, a step towards a unified ionisation source for mass spectrometry?
title_full_unstemmed “GlowFlow”, a step towards a unified ionisation source for mass spectrometry?
title_sort “GlowFlow”, a step towards a unified ionisation source for mass spectrometry?
author_id_str_mv d58c5d38a44d72be924cdf2e1b62ad9f
b17cebaf09b4d737b9378a3581e3de93
6ec1cbca144a41ccf2ee5d89e5587468
author_id_fullname_str_mv d58c5d38a44d72be924cdf2e1b62ad9f_***_Rhodri Owen
b17cebaf09b4d737b9378a3581e3de93_***_Steven Kelly
6ec1cbca144a41ccf2ee5d89e5587468_***_Anthony Brenton
author Rhodri Owen
Steven Kelly
Anthony Brenton
author2 Rhodri Owen
Steven Kelly
Anthony Brenton
format Journal article
container_title Spectroscopy Europe
container_volume 33
container_issue 8
container_start_page 19
publishDate 2021
institution Swansea University
issn 2634-2561
doi_str_mv 10.1255/sew.2021.a53
publisher IM Publications Open LLP
college_str Faculty of Medicine, Health and Life Sciences
hierarchytype
hierarchy_top_id facultyofmedicinehealthandlifesciences
hierarchy_top_title Faculty of Medicine, Health and Life Sciences
hierarchy_parent_id facultyofmedicinehealthandlifesciences
hierarchy_parent_title Faculty of Medicine, Health and Life Sciences
department_str Swansea University Medical School - Medicine{{{_:::_}}}Faculty of Medicine, Health and Life Sciences{{{_:::_}}}Swansea University Medical School - Medicine
document_store_str 1
active_str 0
description Mass spectrometry is a gold-standard analytical technique and is widely employed over a range of fields, from petrochemical, fine chemical through to medical applications. The types of instrumentation for sample separation, ionisation, mass analysis and detection that have evolved in analytical mass spectrometry are diverse; as the old colloquialism goes “it is a matter of horses for courses”. Our “GlowFlow” source design based on an Argon flowing glow-discharge may satisfy part of that landscape.