Impact of a HVDC Link on the Reliability of the Bulk Nigerian Transmission Network

Omowumi Olasunkanmi, Waliu O. Apena, Andrew Barron Orcid Logo, Alvin Orbaek White Orcid Logo, Grazia Todeschini

Energies, Volume: 15, Issue: 24, Start page: 9631

Swansea University Authors: Omowumi Olasunkanmi, Andrew Barron Orcid Logo, Alvin Orbaek White Orcid Logo, Grazia Todeschini

  • 62192.pdf

    PDF | Version of Record

    Copyright: © 2022 by the authors. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license

    Download (1.23MB)

Check full text

DOI (Published version): 10.3390/en15249631

Abstract

Regular and reliable access to energy is critical to the foundations of a stable and growing economy. The Nigerian transmission network generates more electricity than is consumed but, due to unpredicted outages, customers are often left without electrical power for several hours during the year. Th...

Full description

Published in: Energies
ISSN: 1996-1073
Published: MDPI AG 2022
Online Access: Check full text

URI: https://cronfa.swan.ac.uk/Record/cronfa62192
Tags: Add Tag
No Tags, Be the first to tag this record!
Abstract: Regular and reliable access to energy is critical to the foundations of a stable and growing economy. The Nigerian transmission network generates more electricity than is consumed but, due to unpredicted outages, customers are often left without electrical power for several hours during the year. This paper aims to assess the present reliability indices of the Nigerian transmission network, and to determine the impact of HVDCs on system reliability. In the first part of this paper, the reliability of the Nigerian transmission system is quantified by building a model in DIgSILENT PowerFactory and carrying out a reliability study based on data provided by the Nigerian transmission-system operator. Both network indices and load-point indices are evaluated, and the weakest points in the network are identified. In the second part of the paper, an HVDC model is built and integrated into the existing network at the locations identified by the reliability study. A comparative study using two different HVDC connections is then carried out, to determine the critical impact of HVDC on system reliability. The reliability results indicate that the weakest points of the transmission system are the radial feeders, and the highest impact could be achieved by spanning an HVDC line between two busbars located at the two extremes of a radial feeder: Azura and Yola.
Keywords: load-point indices; reliability; VSC-HVDC; transmission network
College: Faculty of Science and Engineering
Funders: This research was supported by the Tertiary Education Trust Fund (TETFUND) under the Academic Staff Training & Development (AST&D) program of the Federal Republic of Nigeria and by the UK Engineering and Physical Sciences Research Council (EPSRC) grant EP/T013206/2. TETFUND’s support to produce this publication does not constitute an endorsement of the contents, which reflect the views only of the authors, and the Commission cannot be held responsible for any use which may be made of the information contained therein.