No Cover Image

E-Thesis 273 views 78 downloads

Forecast-based Energy Management Systems / AMEENA AL-SOROUR

Swansea University Author: AMEENA AL-SOROUR

  • 2023_Al-Sorour_A.final.64638.pdf

    PDF | E-Thesis – open access

    Copyright: The Author, Ameena Al-Sorour, 2023.

    Download (2.7MB)

DOI (Published version): 10.23889/SUthesis.64638

Abstract

The high integration of distributed energy resources into the domestic level has led to an increase in the number of consumers becoming prosumers (producer + customer), which creates several challenges for network operators, such as controlling renewable energy sources over-generation. Recently, sel...

Full description

Published: Swansea, Wales, UK 2023
Institution: Swansea University
Degree level: Doctoral
Degree name: Ph.D
Supervisor: Fazeli, M. and Monfared, M.
URI: https://cronfa.swan.ac.uk/Record/cronfa64638
Tags: Add Tag
No Tags, Be the first to tag this record!
Abstract: The high integration of distributed energy resources into the domestic level has led to an increase in the number of consumers becoming prosumers (producer + customer), which creates several challenges for network operators, such as controlling renewable energy sources over-generation. Recently, self-consumption as a new approach is encouraged by several countries to reduce the dependency on the national grid. This work presents two different Energy Management System (EMS) algorithms for a domestic Photovoltaic (PV) system: (a) real-time Fuzzy Logic-based EMS (FL-EMS) and (b) day-ahead Mixed Integer Linear Programming-based EMS (MILP-EMS). Both methods are tested using the data from the Active Office Building (AOB) located in Swansea University, Bay Campus, UK, as a case study to demonstrate the developed EMSs. AOB comprises a PV system and a Li-ion Battery Storage System (BSS) connected to the grid. The MILP-EMS is used to develop a Community Energy Management System (CEMS) to facilitate local energy exchange. CEMS is tested using the data from six houses located in London, UK, to form a community. Each household comprises a PV system and BSS connected to the grid. It is assumed that all six households use an EV and are equipped with a bidirectional charger to facilitate the Vehicle to House (V2H) mode. In addition, two shiftable appliances are considered to shift the demand to the times when PV generation is maximum to maximise community local consumption. MATLAB software is used to code the proposed systems. The FL-EMS exploits day-ahead energy forecast (assumed it is available from a third party) to control the BSS with the aim of reducing the net energy exchange with the grid by enhancing PV self-consumption. The FL-EMS determines the optimal settings for the BSS, taking into consideration the BSS's state of health to maximise its lifetime. The results are compared with recently published works to demonstrate the effectiveness of the proposed method. The proposed FL-EMS saves 18% on total energy costs in six months compared to a similar system that utilises a day-ahead energy forecast. In addition, the method shows a considerable reduction in the net energy exchanged between the AOB and the grid. The main objective of the MILP-EMS is to reduce the net energy exchange with the grid by including a two days-ahead energy forecast in the optimisation process. The proposed method reduces the total operating costs (energy cost + BSS degradation cost) by up to 35% over six months and reduces net energy exchanged with the grid compared to similar energy optimisation technique. The proposed cost function in MILP-EMS shows that it can outperform the performance of alternative cost function that directly reduce the net energy exchange. CEMS uses two days-ahead energy forecast to reduce the net energy exchange with the grid by coordinating the distributed BSSs. The proposed CEMS reduces the total operating costs (energy costs + BSSs degradation costs) of the community by 7.6% when compared to the six houses being operated individually. In addition, the proposed CEMS enhances community self-consumption by reducing the net energy exchange with the grid by 25.3% over four months compared to similar community energy optimisation technique. A further reduction in operating costs is achieved using V2H mode and including shiftable appliances. Results show that introducing the V2H mode reduces both the total operating costs of the community and the net energy exchange with the grid.
Item Description: Results in Chapters 3, 4, and 6: Distributed under the terms of a Creative Commons Attribution 4.0 License (CC BY 4.0). Results in Chapter 5: Distributed under the terms of a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License (CC BY-NC-ND 4.0).
Keywords: Energy management system, peer-to-peer energy trading
College: Faculty of Science and Engineering