No Cover Image

Journal article 42 views 9 downloads

A Direct Measurement of the C2H2 Concentration from the C2H2–Oil Mixed Solution Using the Photoacoustic Spectroscopy Method

Zikang Rong, Jian Ke, Haifei Lu, Xiaoyan Wen, Lijie Li Orcid Logo, Zhiwen Ming, Shuo Deng Orcid Logo, Min Li Orcid Logo

Photonics, Volume: 12, Issue: 5, Start page: 471

Swansea University Author: Lijie Li Orcid Logo

  • photonics-12-00471-v2.pdf

    PDF | Version of Record

    © 2025 by the authors. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.

    Download (4.32MB)

Abstract

The photoacoustic (PA) method is commonly used in the measurement of trace gas concentration owing to its high accuracy and reliability. However, the conventional PA method is usually used in the gas-phase environment, which leads to a long measurement time and a large equipment volume for the degas...

Full description

Published in: Photonics
ISSN: 2304-6732
Published: MDPI 2025
Online Access: Check full text

URI: https://cronfa.swan.ac.uk/Record/cronfa69655
Abstract: The photoacoustic (PA) method is commonly used in the measurement of trace gas concentration owing to its high accuracy and reliability. However, the conventional PA method is usually used in the gas-phase environment, which leads to a long measurement time and a large equipment volume for the degassing process. In this paper, we report a scheme to measure the acetylene (C2H2) concentration from the acetylene–dielectric oil (C2H2–Oil) mixed solution without the degassing process. The frequency and intensity distribution of the PA signal in the C2H2–Oil mixed liquid is investigated using the finite element method (FEM). Simulation results reveal that the incident light modulation frequency and the geometry size of the PA cell are two core factors to determine the PA signal. Furthermore, a PA sensor system is constructed to measure the concentration of C2H2 from the C2H2–Oil mixed solution. The measurement results demonstrate that the intensity of the PA signal in the C2H2–Oil mixed solution rises mostly linearly with the concentration of C2H2 from 0 to 100 mL/L. The Allan variance results from the continuous tests indicate that the measurement limit of the PA sensor system is about 0.2 mL/L. This work points to a novel method for the measurement of the C2H2 concentration from the C2H2–Oil mixed solution.
Keywords: photoacoustic spectroscopy; gas–liquid mixed solution; direct measurement; acetylene concentration
College: Faculty of Science and Engineering
Funders: National Natural Science Foundation of China (62304161); Key R&D Program of Hubei Province (2024BAB009).
Issue: 5
Start Page: 471