No Cover Image

Journal article 837 views 175 downloads

Comparison of head impact measurements via an instrumented mouthguard and an anthropometric testing device

Desney Greybe, Christopher M. Jones Orcid Logo, Rowan Brown Orcid Logo, Elisabeth Williams Orcid Logo

Sports Engineering, Volume: 23, Issue: 1

Swansea University Authors: Desney Greybe, Christopher M. Jones Orcid Logo, Rowan Brown Orcid Logo, Elisabeth Williams Orcid Logo

  • 54405.pdf

    PDF | Version of Record

    This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.

    Download (1.73MB)

Abstract

The purpose of this study was to determine and compare the efficacy of head impact measurements via an electronic sensor framework, embedded within a mouthguard, against an anthropometric testing device. Development of the former is in response to the growing issue of head impacts and concussion in...

Full description

Published in: Sports Engineering
ISSN: 1369-7072 1460-2687
Published: Springer Science and Business Media LLC 2020
Online Access: Check full text

URI: https://cronfa.swan.ac.uk/Record/cronfa54405
Tags: Add Tag
No Tags, Be the first to tag this record!
Abstract: The purpose of this study was to determine and compare the efficacy of head impact measurements via an electronic sensor framework, embedded within a mouthguard, against an anthropometric testing device. Development of the former is in response to the growing issue of head impacts and concussion in rugby union. Testing was conducted in a vehicle safety laboratory using a standard impact protocol utilising the headforms of anthropometric testing devices. The headforms were subjected to controlled front and side impacts. For each impact, the linear acceleration and rotational velocity was measured over a 104-ms interval at a frequency of 1 kHz. The magnitude of peak linear acceleration and peak rotational velocity was determined from the measured time-series traces and statistically compared. The peak linear acceleration and rotational velocity had intraclass correlation coefficients of 0.95 and 0.99, respectively. The root-mean-square error between the measurement systems was 4.3 g with a standard deviation of 3.5 g for peak linear acceleration and 0.7 rad/s with a standard deviation of 0.4 rad/s for rotational velocity. Bland and Altman analysis indicated a systematic bias of 2.5 g and − 0.5 rad/s and limits of agreement (1.96 × standard deviation) of ± 13.1 g and ± 1.25 rad/s for the instrumented mouthguard. These results provide the basis on which the instrumented mouthguard can be further developed for deployment and application within professional rugby, with a view to accurately and reliably quantify head collision dynamics.
Issue: 1