No Cover Image

Journal article 71 views 15 downloads

Comparability Evaluation of Three Benchtop Glucose Analyzers With the Recently Withdrawn YSI 2300 Stat Plus

Gareth Dunseath Orcid Logo, IULIUS-DUMITRU VATAVU, Steve Luzio Orcid Logo

Journal of Diabetes Science and Technology

Swansea University Authors: Gareth Dunseath Orcid Logo, IULIUS-DUMITRU VATAVU, Steve Luzio Orcid Logo

  • 66252.VoR.pdf

    PDF | Version of Record

    © 2024 Diabetes Technology Society. This article is distributed under the terms of the Creative Commons Attribution 4.0 License.

    Download (249.91KB)

Abstract

Background:We compared the performance of three currently available laboratory benchtop glucose analyzers with the outgoing YSI 2300 Stat Plus.Methods:Plasma samples (100), across a wide glucose concentration range were analysed on the YSI 2500, Randox daytona+ (glucose oxidase) and EKF Biosen in a...

Full description

Published in: Journal of Diabetes Science and Technology
ISSN: 1932-2968 1932-2968
Published: SAGE Publications 2024
Online Access: Check full text

URI: https://cronfa.swan.ac.uk/Record/cronfa66252
Tags: Add Tag
No Tags, Be the first to tag this record!
first_indexed 2024-05-31T13:39:48Z
last_indexed 2024-05-31T13:39:48Z
id cronfa66252
recordtype SURis
fullrecord <?xml version="1.0" encoding="utf-8"?><rfc1807 xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:xsd="http://www.w3.org/2001/XMLSchema"><bib-version>v2</bib-version><id>66252</id><entry>2024-05-02</entry><title>Comparability Evaluation of Three Benchtop Glucose Analyzers With the Recently Withdrawn YSI 2300 Stat Plus</title><swanseaauthors><author><sid>fccbba9edcaee08a839a3c5cff8cbe19</sid><ORCID>0000-0001-6022-862X</ORCID><firstname>Gareth</firstname><surname>Dunseath</surname><name>Gareth Dunseath</name><active>true</active><ethesisStudent>false</ethesisStudent></author><author><sid>0bfccb4e00b76351ba35a021a247e99c</sid><firstname>IULIUS-DUMITRU</firstname><surname>VATAVU</surname><name>IULIUS-DUMITRU VATAVU</name><active>true</active><ethesisStudent>false</ethesisStudent></author><author><sid>01491e1cd582746a654fad9addf0de16</sid><ORCID>0000-0002-7206-6530</ORCID><firstname>Steve</firstname><surname>Luzio</surname><name>Steve Luzio</name><active>true</active><ethesisStudent>false</ethesisStudent></author></swanseaauthors><date>2024-05-02</date><deptcode>MEDS</deptcode><abstract>Background:We compared the performance of three currently available laboratory benchtop glucose analyzers with the outgoing YSI 2300 Stat Plus.Methods:Plasma samples (100), across a wide glucose concentration range were analysed on the YSI 2500, Randox daytona+ (glucose oxidase) and EKF Biosen in a single laboratory and compared to the YSI 2300 Stat Plus.Results:All three analyzers showed good agreement with the YSI 2300 Stat Plus, and only a small bias (≤1% YSI 2500 and Randox daytona+, 4.6% EKF Biosen) was observed for each analyzer. None of the three comparator analyzers were affected by either proportional or constant bias, thus no significant differences between the YSI 2300 Stat Plus and the comparator methods were identified.Conclusions:The results from this study suggest all could be considered as suitable reference laboratory glucose analyzers and replacements for the recently withdrawn YSI 2300 Stat Plus.</abstract><type>Journal Article</type><journal>Journal of Diabetes Science and Technology</journal><volume>0</volume><journalNumber/><paginationStart/><paginationEnd/><publisher>SAGE Publications</publisher><placeOfPublication/><isbnPrint/><isbnElectronic/><issnPrint>1932-2968</issnPrint><issnElectronic>1932-2968</issnElectronic><keywords>analyzer; glucose; comparison</keywords><publishedDay>8</publishedDay><publishedMonth>2</publishedMonth><publishedYear>2024</publishedYear><publishedDate>2024-02-08</publishedDate><doi>10.1177/19322968241230337</doi><url/><notes/><college>COLLEGE NANME</college><department>Medical School</department><CollegeCode>COLLEGE CODE</CollegeCode><DepartmentCode>MEDS</DepartmentCode><institution>Swansea University</institution><apcterm>SU Library paid the OA fee (TA Institutional Deal)</apcterm><funders>Swansea University</funders><projectreference/><lastEdited>2024-05-31T14:41:59.4294190</lastEdited><Created>2024-05-02T20:45:58.7590207</Created><path><level id="1">Faculty of Medicine, Health and Life Sciences</level><level id="2">Swansea University Medical School - Biomedical Science</level></path><authors><author><firstname>Gareth</firstname><surname>Dunseath</surname><orcid>0000-0001-6022-862X</orcid><order>1</order></author><author><firstname>IULIUS-DUMITRU</firstname><surname>VATAVU</surname><order>2</order></author><author><firstname>Steve</firstname><surname>Luzio</surname><orcid>0000-0002-7206-6530</orcid><order>3</order></author></authors><documents><document><filename>66252__30500__ee11bcee573e4fc0b566b2ae97fcb0ba.pdf</filename><originalFilename>66252.VoR.pdf</originalFilename><uploaded>2024-05-31T14:40:27.2598894</uploaded><type>Output</type><contentLength>255904</contentLength><contentType>application/pdf</contentType><version>Version of Record</version><cronfaStatus>true</cronfaStatus><documentNotes>© 2024 Diabetes Technology Society. This article is distributed under the terms of the Creative Commons Attribution 4.0 License.</documentNotes><copyrightCorrect>true</copyrightCorrect><language>eng</language><licence>https://creativecommons.org/licenses/by/4.0/</licence></document></documents><OutputDurs/></rfc1807>
spelling v2 66252 2024-05-02 Comparability Evaluation of Three Benchtop Glucose Analyzers With the Recently Withdrawn YSI 2300 Stat Plus fccbba9edcaee08a839a3c5cff8cbe19 0000-0001-6022-862X Gareth Dunseath Gareth Dunseath true false 0bfccb4e00b76351ba35a021a247e99c IULIUS-DUMITRU VATAVU IULIUS-DUMITRU VATAVU true false 01491e1cd582746a654fad9addf0de16 0000-0002-7206-6530 Steve Luzio Steve Luzio true false 2024-05-02 MEDS Background:We compared the performance of three currently available laboratory benchtop glucose analyzers with the outgoing YSI 2300 Stat Plus.Methods:Plasma samples (100), across a wide glucose concentration range were analysed on the YSI 2500, Randox daytona+ (glucose oxidase) and EKF Biosen in a single laboratory and compared to the YSI 2300 Stat Plus.Results:All three analyzers showed good agreement with the YSI 2300 Stat Plus, and only a small bias (≤1% YSI 2500 and Randox daytona+, 4.6% EKF Biosen) was observed for each analyzer. None of the three comparator analyzers were affected by either proportional or constant bias, thus no significant differences between the YSI 2300 Stat Plus and the comparator methods were identified.Conclusions:The results from this study suggest all could be considered as suitable reference laboratory glucose analyzers and replacements for the recently withdrawn YSI 2300 Stat Plus. Journal Article Journal of Diabetes Science and Technology 0 SAGE Publications 1932-2968 1932-2968 analyzer; glucose; comparison 8 2 2024 2024-02-08 10.1177/19322968241230337 COLLEGE NANME Medical School COLLEGE CODE MEDS Swansea University SU Library paid the OA fee (TA Institutional Deal) Swansea University 2024-05-31T14:41:59.4294190 2024-05-02T20:45:58.7590207 Faculty of Medicine, Health and Life Sciences Swansea University Medical School - Biomedical Science Gareth Dunseath 0000-0001-6022-862X 1 IULIUS-DUMITRU VATAVU 2 Steve Luzio 0000-0002-7206-6530 3 66252__30500__ee11bcee573e4fc0b566b2ae97fcb0ba.pdf 66252.VoR.pdf 2024-05-31T14:40:27.2598894 Output 255904 application/pdf Version of Record true © 2024 Diabetes Technology Society. This article is distributed under the terms of the Creative Commons Attribution 4.0 License. true eng https://creativecommons.org/licenses/by/4.0/
title Comparability Evaluation of Three Benchtop Glucose Analyzers With the Recently Withdrawn YSI 2300 Stat Plus
spellingShingle Comparability Evaluation of Three Benchtop Glucose Analyzers With the Recently Withdrawn YSI 2300 Stat Plus
Gareth Dunseath
IULIUS-DUMITRU VATAVU
Steve Luzio
title_short Comparability Evaluation of Three Benchtop Glucose Analyzers With the Recently Withdrawn YSI 2300 Stat Plus
title_full Comparability Evaluation of Three Benchtop Glucose Analyzers With the Recently Withdrawn YSI 2300 Stat Plus
title_fullStr Comparability Evaluation of Three Benchtop Glucose Analyzers With the Recently Withdrawn YSI 2300 Stat Plus
title_full_unstemmed Comparability Evaluation of Three Benchtop Glucose Analyzers With the Recently Withdrawn YSI 2300 Stat Plus
title_sort Comparability Evaluation of Three Benchtop Glucose Analyzers With the Recently Withdrawn YSI 2300 Stat Plus
author_id_str_mv fccbba9edcaee08a839a3c5cff8cbe19
0bfccb4e00b76351ba35a021a247e99c
01491e1cd582746a654fad9addf0de16
author_id_fullname_str_mv fccbba9edcaee08a839a3c5cff8cbe19_***_Gareth Dunseath
0bfccb4e00b76351ba35a021a247e99c_***_IULIUS-DUMITRU VATAVU
01491e1cd582746a654fad9addf0de16_***_Steve Luzio
author Gareth Dunseath
IULIUS-DUMITRU VATAVU
Steve Luzio
author2 Gareth Dunseath
IULIUS-DUMITRU VATAVU
Steve Luzio
format Journal article
container_title Journal of Diabetes Science and Technology
container_volume 0
publishDate 2024
institution Swansea University
issn 1932-2968
1932-2968
doi_str_mv 10.1177/19322968241230337
publisher SAGE Publications
college_str Faculty of Medicine, Health and Life Sciences
hierarchytype
hierarchy_top_id facultyofmedicinehealthandlifesciences
hierarchy_top_title Faculty of Medicine, Health and Life Sciences
hierarchy_parent_id facultyofmedicinehealthandlifesciences
hierarchy_parent_title Faculty of Medicine, Health and Life Sciences
department_str Swansea University Medical School - Biomedical Science{{{_:::_}}}Faculty of Medicine, Health and Life Sciences{{{_:::_}}}Swansea University Medical School - Biomedical Science
document_store_str 1
active_str 0
description Background:We compared the performance of three currently available laboratory benchtop glucose analyzers with the outgoing YSI 2300 Stat Plus.Methods:Plasma samples (100), across a wide glucose concentration range were analysed on the YSI 2500, Randox daytona+ (glucose oxidase) and EKF Biosen in a single laboratory and compared to the YSI 2300 Stat Plus.Results:All three analyzers showed good agreement with the YSI 2300 Stat Plus, and only a small bias (≤1% YSI 2500 and Randox daytona+, 4.6% EKF Biosen) was observed for each analyzer. None of the three comparator analyzers were affected by either proportional or constant bias, thus no significant differences between the YSI 2300 Stat Plus and the comparator methods were identified.Conclusions:The results from this study suggest all could be considered as suitable reference laboratory glucose analyzers and replacements for the recently withdrawn YSI 2300 Stat Plus.
published_date 2024-02-08T14:41:58Z
_version_ 1800575824297984000
score 11.016235